Product Description
Power Input |
GD20-UL Input voltage (V) & power |
AC 1PH 110V–120V, rated voltage: 110V 0.4~1.1kW(0.5~1.5HP) AC 1PH 200V–240V, rated voltage: 220V 0.4~2.2kW(0.5~3HP) AC 3PH 200V–240V, rated voltage: 220V 0.4~0.75kW(0.5~1HP)
AC 3PH 380V–480V, rated voltage: 460V 0.75~2.2kW(1~3HP) |
GD20-EU Input voltage (V) & power |
AC 1PH 200V–240V, rated voltage: 230V 0.4~2.2kW(0.5~3HP) AC 3PH 200V–240V, rated voltage: 230V 0.4~2.2kW(0.5~3HP) AC 3PH 380V–480V, rated voltage: 400V 0.75~11kW(1~15HP) | |
Input frequency (Hz) | 50Hz or 60Hz; allowed range: 47 – 63Hz | |
Power Output |
Output voltage (V) | 0 – input voltage |
Output frequency (Hz) | 0 – 400Hz | |
Technical Control Feature |
Control mode | SVPWM, SVC |
Motor | Asynchronous motor | |
Adjustable-speed ratio | Asynchronous motor 1:100 (SVC) | |
Speed control accuracy | ±0.2% (SVC) | |
Speed fluctuation | ±0.3% (SVC) | |
Torque response | <20ms (SVC) | |
Torque control accuracy | 10% | |
Starting torque | 0. 5Hz/150% (SVC) | |
Running Control Feature |
Frequency setting method |
Digital setting, analog setting, pulse frequency setting, multi-step speed running setting, simple PLC setting, PID setting, MODBUS communication setting Shift between the set combination and set channel. |
Auto-adjustment of the voltage | Keep a stable voltage automatically when the grid voltage transients | |
Fault protection |
Provide comprehensive fault protection functions: overcurrent, overvoltage, undervoltage, overheating, phase loss and overload, etc. |
Additional Information
Delivery Time | ready stock |